IEC 61000-4-13-2015 电磁兼容(EMC)--第4-13部分:试验和测量技术--在交流电源端的谐波和谐间波(包括主要信号)的低频抗扰度试验 Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics including mains signalling at a.c. power port, low frequency i
- 标准类别:
- 标准大小:
- 标准编号:IEC 61000-4-13-2015
- 标准状态:现行
- 更新时间:2023-08-28
- 下载次数:次
This part of IEC 61000 defines the immunity test methods and range of recommended basic
test levels for electrical and electronic equipment with rated current up to 16 A per phase at
disturbance frequencies up to and including 2 kHz (for 50 Hz mains) and 2,4 kHz (for 60 Hz
mains) for harmonics and interharmonics on low voltage power networks.
It does not apply to electrical and electronic equipment connected to 16 2/3 Hz , or to 400 Hz
a.c. networks. Tests for these networks will be covered by future standards.
The object of this standard is to establish a common reference for evaluating the functional
immunity of electrical and electronic equipment when subjected to harmonics and inter-
harmonics and mains signalling frequencies. The test method documented in this part of IEC
61000 describes a consistent method to assess the immunity of an equipment or system
against a defined phenomenon. As described in IEC guide 107, this is a basic EMC publication
for use by product committees of the IEC. As also stated in Guide 107, the IEC product
committees are responsible for determining whether this immunity test standard should be
applied or not, and if applied, they are responsible for determining the appropriate test levels
and performance criteria. TC 77 and its sub-committees are prepared to co-operate with
product committees in the evaluation of the value of particular immunity tests for their products.
The verification of the reliability of electrical components (for example capacitors, filters, etc.)
is not in the scope of the present standard. Long term thermal effects (greater than 15 min) are
not considered in this standard.
The levels proposed are more adapted for residential, commercial and light industry
environments. For heavy industrial environments the product committees are responsible for
the definition of a class X with the necessary levels. They have also the possibility of defining
more complex waveforms for their own need. Nevertheless, the simple waveforms proposed
have been mainly observed on several networks (flat curve more often for single phase
system) and also on industrial networks (overswing curve more for three phase systems).dition 1.2 2015-12
CONSOLIDATED
VERSION
VERSION
CONSOLIDéE
colour
inside
BASIC EMC PUBLICATION
PUBLICATION FONDAMENTALE EN CEM
Electromagnetic compatibility (EMC) –
Part 4-13: Testing and measurement techniques – Harmonics and
interharmonics including mains signalling at a.c. power port, low frequency
immunity tests
Compatibilité électromagnétique (CEM) –
Partie 4-13: Techniques d’essai et de mesure – Essais d’immunité basse
fréquence aux harmoniques et inter-harmoniques inclu
-
GB 30871-2022免费下载危险化学品企业特殊作业安全规范 2023-08-28
-
GB/T 1094.1-2013电力变压器 第1部分:总则 2023-08-28
-
GB/T 706-2016热轧型钢 2023-08-28
-
JB/T 10216-2013电控配电用电缆桥架 2023-08-28
-
GB 9706.1-2020医用电气设备 第1部分:基本安全和基本性能的通用要求 2023-08-28
-
GB/T 10801.2-2018绝热用挤塑聚苯乙烯泡沫塑料(XPS) 2023-08-28
-
GB 51251-2017建筑防烟排烟系统技术标准 2023-08-28
-
GB/T 13663.2-2018给水用聚乙烯(PE)管道系统 第2部分:管材 2023-08-28