ISO 19581-2017 利用闪烁探测器伽马射线光谱法测量放射性--伽马辐射-快速筛选方法 Measurement of radioactivity — Gamma emitting radionuclides — Rapid screening method using scintillation detector gamma-ray spectrometry
- 标准类别:
- 标准大小:
- 标准编号:ISO 19581-2017
- 标准状态:现行
- 更新时间:2023-10-03
- 下载次数:次
This document specifies a screening test method to quantify rapidly the activity concentration of 131 132 134 137 gamma-emitting radionuclides, such as I, Te, Cs and Cs, in solid or liquid test samples using gamma-ray spectrometry with lower resolution scintillation detectors as compared with the HPGe detectors (see IEC 61563).
This test method can be used for the measurement of any potentially contaminated environmental matrices (including soil), food and feed samples as well as industrial materials or products that have been properly conditioned. Sample preparation techniques used in the screening method are not specified in this document, since special sample preparation techniques other than simple machining (cutting, grinding, etc.) should not be required. Although the sampling procedure is of utmost importance in the case of the measurement of radioactivity in samples, it is out of scope of this document; other international standards for sampling procedures that can be used in combination with this document are available (see References [1],[2],[3],[4],[5],[6]). 131 134
The test method applies to the measurement of gamma-emitting radionuclides such as I, Cs 137 and Cs. Using sample sizes of 0,5 l to 1,0 l in a Marinelli beaker and a counting time of 5 min to −1 20 min, decision threshold of 10 Bq·kg can be achievable using a commercially available scintillation spectrometer [e.g. thallium activated sodium iodine (NaI(Tl)) spectrometer 2” ? × 2” detector size, 7 % resolution (FWHM) at 662 keV, 30 mm lead shield thickness].
This test method also can be performed in a “makeshift” laboratory or even outside a testing laboratory on samples directly measured in the field where they were collected. During a nuclear or radiological emergency, this test method enables a rapid measurement of the sample activity concentration of potentially contaminated samples to check against operational intervention levels (OILs) set up by decision makers that would trigger a predetermined emergency response to [12] reduce existing radiation risks .
Due to the uncertainty associated with the results obtained with this test method, test samples requiring more accurate test results can be measured using high-purity germanium (HPGe) detectors gamma-ray [7][8] spectrometry in a testing laboratory, following appropriate preparation of the test samples .
This document does not contain criteria to establish the activity concentration of OILs.st edition
2017-10
Measurement of radioactivity —
Gamma emitting radionuclides
— Rapid screening method using
scintillation detector gamma-ray
spectrometry
Mesurage de la radioactivité — Radionucléides émetteurs gamma —
Méthode d'essai de dépistage par spectrométrie gamma utilisant des
détecteurs par scintillation
Reference number
ISO 19581:2017(E)
?
ISO 2017
ISO 19581:2017(E)
COPYRI
-
GB 30871-2022免费下载危险化学品企业特殊作业安全规范 2023-10-03
-
GB/T 1094.1-2013电力变压器 第1部分:总则 2023-10-03
-
GB/T 706-2016热轧型钢 2023-10-03
-
JB/T 10216-2013电控配电用电缆桥架 2023-10-03
-
GB 9706.1-2020医用电气设备 第1部分:基本安全和基本性能的通用要求 2023-10-03
-
GB/T 10801.2-2018绝热用挤塑聚苯乙烯泡沫塑料(XPS) 2023-10-03
-
GB/T 13663.2-2018给水用聚乙烯(PE)管道系统 第2部分:管材 2023-10-03
-
GB 51251-2017建筑防烟排烟系统技术标准 2023-10-03