IEC 62209-2-2019 人体接触射频领域从手持body-mounted无线通信设备,人体模型,仪表,和程序--第2部分:过程来确定特定吸收率(SAR)为无线通信设备中使用靠近人体(30 MHz到6 GHz的频率范围) Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices – Human models, instrumentation
- 标准类别:
- 标准大小:
- 标准编号:IEC 62209-2-2019
- 标准状态:现行
- 更新时间:2024-01-19
- 下载次数:次
This part of IEC 62209 series is applicable to any wireless communication device capable of
transmitting electromagnetic fields (EMF) intended to be used at a position near the human
body, in the manner described by the manufacturer, with the radiating part(s) of the device at
distances up to and including 200 mm from a human body, i.e. when held in the hand or in
front of the face, mounted on the body, combined with other transmitting or non-transmitting
devices or accessories (e.g. belt-clip, camera or Bluetooth add-on), or embedded in
garments. For transmitters used in close proximity to the human ear, the procedures of
IEC 62209-1:2005 are applicable.
This standard is applicable for radio frequency exposure in the frequency range of 30 MHz to
6 GHz, and may be used to measure simultaneous exposures from multiple radio sources
used in close proximity to human body. Definitions and evaluation procedures are provided for
the following general categories of device types: body-mounted, body-supported, desktop,
front-of-face, hand-held, laptop, limb-mounted, multi-band, push-to-talk, clothing-integrated.
The types of devices considered include but are not limited to mobile telephones, cordless
microphones, auxiliary broadcast devices and radio transmitters in personal computers.
This International Standard gives guidelines for a reproducible and conservative
measurement methodology for determining the compliance of wireless devices with the SAR
limits.
Because studies suggest that exclusion of features to represent a hand in human models
constitutes a conservative case scenario for SAR in the trunk and the head, a representation
of a hand is not included if the device is intended to be used next to the head or supported on
or near the torso [73], [80]. This standard does not apply for exposures from transmitting or
non-transmitting implanted medical devices. This standard does not apply for exposure from
devices at distances greater than 200 mm away from the human body.
IEC 62209-2 makes cross-reference to IEC 62209-1:2005 where complete clauses or
subclauses apply, along with any changes specified.dition 1.1 2019-05
CONSOLIDATED
VERSION
VERSION
CONSOLIDéE
colour
inside
Human exposure to radio frequency fields from hand-held and body-mounted
wireless communication devices –
Human models, instrumentation, and procedures –
Part 2: Procedure to determine the specific absorption rate (SAR) for wireless
communication devices used in close proximity to the human body (frequency
range of 30 MHz to 6 GHz)
Exposition humaine aux champs radiofréquence produits par les dispositifs
-
GB 30871-2022免费下载危险化学品企业特殊作业安全规范 2024-01-19
-
GB/T 706-2016热轧型钢 2024-01-19
-
GB/T 1094.1-2013电力变压器 第1部分:总则 2024-01-19
-
JB/T 10216-2013电控配电用电缆桥架 2024-01-19
-
GB/T 13663.2-2018给水用聚乙烯(PE)管道系统 第2部分:管材 2024-01-19
-
GB 9706.1-2020医用电气设备 第1部分:基本安全和基本性能的通用要求 2024-01-19
-
GB/T 10801.2-2018绝热用挤塑聚苯乙烯泡沫塑料(XPS) 2024-01-19
-
YB/T 4001.1-2019钢格栅板及配套件 第1部分:钢格栅板 2024-01-19
-
GB 51251-2017建筑防烟排烟系统技术标准 2024-01-19