ASTM E3057-2019 用带先进技术分析技术的定向火焰温度计测量热通量的试验方法 Standard Test Method for Measuring Heat Flux Using Directional Flame Thermometers with Advanced Data Analysis Techniques
<div class="SectionLevel2"> <p class="subsec1 cdone2"><span class="Head3 cdone">1.1</span> This test method describes the continuous measurement of the hemispherical heat flux to one or both surfaces of an uncooled sensor called a “Directional Flame Thermometer” (DFT).</p></div> <div class="SectionLevel2"> <p class="subsec1 cdone2"><span class="Head3 cdone">1.2</span> DFTs consist of two heavily oxidized, Inconel 600 plates with mineral insulated, metal-sheathed (MIMS) thermocouples (TCs, type K) attached to the unexposed faces and a layer of ceramic fiber insulation placed between the plates.</p></div> <div class="SectionLevel2"> <p class="subsec1 cdone2"><span class="Head3 cdone">1.3</span> Post-test calculations of the net heat flux can be made using several methods. The most accurate method uses an inverse heat conduction code. Nonlinear inverse heat conduction analysis uses a thermal model of the DFT with temperature dependent thermal properties along with the two plate temperature measurement histories. The code provides transient heat flux on both exposed faces, temperature histories within the DFT as well as statistical information on the quality of the analysis.</p></div> <div class="SectionLevel2"> <p class="subsec1 cdone2"><span class="Head3 cdone">1.4</span> A second method uses a transient energy balance on the DFT sensing surface and insulation, which uses the same temperature measurements as in the inverse calculations to estimate the net heat flux.</p></div> <div class="SectionLevel2"> <p class="subsec1 cdone2"><span class="Head3 cdone">1.5</span> A third method uses Inverse Filter Functions (IFFs) to provide a near real time estimate of the net flux. The heat flux history for the “front face” (either surface exposed to the heat source) of a DFT can be calculated in real-time using a convolution type of digital filter algorithm.</p></div> <div class="SectionLevel2"> <p class="subsec1 cdon...
2023-08-22 11:24:01浏览:22
查看 -
GB/T 19216.3-2021 在火焰条件下电缆或光缆的线路完整性试验 第3部分:火焰温度不低于830 ℃的供火并施加冲击振动,额定电压0.6/1 kV及以下电缆穿在金属管中进行的试验方法 Circuit integrity test for electric cables or optical fiber cables under fire conditions- Part 3: Test method for fire with shock at a temperature of at least
本文件描述了耐火电缆穿在金属管中受到规定条件下的火焰和冲击振动时应保持线路完整性的试验方法。<br />本文件适用于额定电压0.6/1kV及以下的电缆,包括额定电压低于80V的金属导体数据和电信电缆及光缆。<br />本文件适用于外径小于或等于20mm的试验电缆。<br />本文件描述了额定电压0.6/1kV及以下电力电缆和控制电缆的试验失败点、连续性检查装置、试验样品、试验程序和试验报告的详细信息。未给出金属导体数据和电信电缆及光缆的试验失败点、连续性检查装置、试验样品、试验程序和试验报告的详细信息。<br />虽然适用范围仅局限于额定电压0.6/1kV及以下的电缆,但当制造厂和买方同意,并配备合适的熔断器后,也能适用于额定电压1.8/3(3.3)kV及以下的电缆。<br />不假定用此方法评估成功的电缆也能通过GB/T19216.1-<font class="font-highlight">2021</font>或GB/T19216.2-<font class="font-highlight">2021</font>的要求。对这两个标准中任何一个的试验都要分别进行。根据GB/T19216.1-<font class="font-highlight">2021</font>第11章或GB/T19216.2-<font class="font-highlight">2021</font>第11章的规定,这种额外的性能能通过标记来识别。<br />附录A给出了试验用燃烧器和控制系统的验证方法。<br /> ...
2023-08-21 20:36:01浏览:25
查看 -
GB/T 19216.3-2021在火焰条件下电缆或光缆的线路完整性试验 第3部分:火焰温度不低于830 ℃的供火并施加冲击振动,额定电压0.6/1 kV及以下电缆穿在金属管中进行的试验方法Circuit integrity test for electric cables or optical fiber cables under fire conditions—Part 3: Test method for fire with shock at a temperature of at least 83
本文件描述了耐火电缆受到规定条件下的火焰和冲击振动时应保持线路完整性的试验方法适用于额定电压0.6/1kV及以下的电缆,包括额定电压低于80V的金属导体数据和电信电缆及光缆。本文件适用于外径小于或等于20 mm的试验电缆。本文件描述了额定电压0.6/1 kV及以下电力电缆和控制电缆的试验失败点、连续性检查装置,试验样品﹑试验程序和试验报告的详细信息。未给出金属导体数据和电信电缆及光缆的试验失败点、连续性检查装置.试验样品、试验程序和试验报告的详细信息。虽然适用范围仅局限于额定电压0.6/1 kV及以下的电缆,但当制造厂和买方同意,并配备合适的熔断器后,能适用于额定电压1.8/3(3.3) kV及以下的电缆。不假定用此方法评估成功的电缆也能通过GB/T 19216.1-2021或GB/T 19216.2-2021的要求。对这两个标准中任何一个的试验都要分别进行。根据GB/T 19216.1-2021第11章或GB/T 19216.2-2021第11章的规定,这种额外的性能能通过标记来识别。附录A给出了试验用燃烧器和控制系统的验证方法。警示:本文件中的试验可能涉及使用危险的电压和温度。宜采...
2022-10-24 06:51:01浏览:44
查看 -
GB/T 19216.1-2021在火焰条件下电缆或光缆的线路完整性试验 第1部分:火焰温度不低于830 ℃的供火并施加冲击振动,额定电压0.6/1 kV及以下外径超过20 mm电缆的试验方法Circuit integrity test for electric cables or optical fiber cables under fire conditions—Part 1: Test method for fire with shock at a temperature of at least 8
试验方法描述了耐火电缆受到规定条件下的火焰和冲击振动时应保持线路完整性的试验方法。本文件适用于额定电压0.6/1kV及以下的电缆,包括额定电压低于80V的金属导体数据和电信电缆及光缆。本文件适用于外径大于20 mm的试验电缆。直径较小的电缆将使用GB/T 19216.2的设备、程序和要求进行试验。本文件描述了额定电压0.6/1 kV及以下电力电缆和控制电缆的试验失败点、连续性检查装置,试验样品﹑试验程序和试验报告的详细信息。未给出金属导体数据和电信电缆及光缆的试验失败点、连续性检查装置.试验样品、试验程序和试验报告的详细信息。虽然适用范围仅局限于额定电压0.6/1 kV及以下的电缆,但当制造厂和买方同意,并配备合适的熔断器后,能适用于额定电压1.8/3(3.3) kV及以下的电缆。附录A给出了试验用燃烧器和控制系统的验证方法。需要识别标识时可选择在电缆上标记,以表示符合本文件。警示:本文件中的试验可能涉及使用危险的电压和温度。宜采取适当的预防措施,防止可能涉及的电击、燃烧、火灾和爆炸的危险,以及可能产生的任何有害气体。...
2022-10-24 06:54:01浏览:50
查看